Call Us:+86-21-63353309
[email protected]
The Bearing Checker is a shock pulse meter based on the well proven SPM method for quick and easy identification of bearing faults. The instrument has a built-in microprocessor programmed to analyze shock pulse patterns from all types of ball and roller bearings and display evaluated information on the operating condition of the bearing.
Learn MoreSPM Instruments. A Shock Pulse Analyser. T2000 Shock Impulse Tester. TAC10 Tachometer. TAC-10 Tachometer, Optical. VIB10 Vibration Meter.
Learn MorePiezoelectric accelerometers take advantage of the piezoelectric effect discovered by Pierre and Jacques Curie in 1880. They observed that certain materials, especially crystals and ceramic, would generate a charge or voltage in response to being stressed. They further saw that this response was linear with respect to the applied stress.
Learn MoreAs these shocks 'ring' the shock pulse transducer, it outputs electric pulses proportional to the shock magnitude. Unlike vibration transducers, the shock pulse transducer responds at its carefully tuned resonance frequency of about 32 kHz, thus allowing a calibrated measurement of the shock pulse amplitudes. Measuring LR/HR
Learn MoreThe CS Q-LEAP™ system is based on the HERO™ vibration controller and the SE-201 shock exciter. It enables secondary calibration of shock-sensors as well as
Learn MoreOur Profile The brand, MCM Instruments emerges as the undisputed conqueror in the arena of manufacturing condition monitoring instruments. The entity is providing the unmatched quality of products like Vibration Test Equipments, Vibration Analyzers, Vibration Data Loggers, Bearing Condition Analyzers, Machine Conditioners, Electric Motor Checkers, Electronic Stethoscope, and other items in the
Learn Morethe measurement and calibration of shock accelerometers . User identification parison techniques when the shock pulse -wavelength" approaches the.
Learn MoreThe shock pulse meter counts the rate of occurrence (incoming shock pulses per second) and varies the gain until two amplitude levels are determined: HR = high rate of occurrence, quantifying the shock carpet (approx. 1000 incoming shocks per second). Calibration. The accuracy of the LR/HR method is increased by a calibration factor (COMP
Learn Moreto generate a shock pulse that is sensed by the reference and test accelero- meters , which are mounted on the carriage.'These transducers produce elec-.
Learn Moreshock calibration of accelerometers. These are described in ISO 16063-22 [1]. The shock methods are applicable for amplitude range from as low as 10 G to above 10,000 G, and a pulse duration range of less than 0.1 ms to 8.0 ms. This report describes a system newly designed to facilitate shock calibration,
Learn MoreISO 16063-22 specifically describes instrumentation and procedures to be used for secondary shock calibration of accelerometers, using a reference acceleration, velocity or force measurement for the time-dependent shock comparison. 4 The methods are applicable in. a shock pulse duration range of 0.05 to 8.0 ms, and a dynamic range (peak value
Learn MoreThe various classical shock pulses have unique purposes. Generally, each of these unipolar pulses excites a wide range of frequencies in a short period of time but in different ways. Classical pulses are primarily defined in acceleration; the shape of the acceleration waveform determines the frequencies and the degree to which they are excited.
Learn MoreThis system can perform calibration and linearity checks up to 10,000 g and is one of the most versatile anvil shock-type devices available for shock calibration in terms of amplitude range,
Learn MoreDigital vibration transducers (DTI) and sensors with a DTI interface can also be calibrated using a sin² pulse. Primary calibration shock sensors
Learn MoreThe HEML operates at 2.54 cm independent of acceleration. Figure 9. Calibration shock pulse (acceleration vs. time ). B. Comparison to other methods. The bungee
Learn More32 kHz, which allows a calibrated measurement of the shock pulse amplitudes. Measurement. The shock pulse meter counts the rate of occurrence (in-.
Learn MoreTable 10. ISO 16063-22 Uncertainty of measurement limits. Shock calibration apparatus. Peak acceleration. Minimum pulse duration. Uncertainty.
Learn MoreEasy to transport mobile concrete plants have axles and tires in its main chassis. Thanks to pre-assembled structure, they can be installed in a very short period of time (1-2 days) View Details
Learn MoreBecause there is no National Institute of Standards and Technology traceable calibration capability at shock levels of 5,000–15,000 g for the
Learn MoreThese shocks 'ring' the SPM transducer which outputs electric pulses proportional to the shock magnitude. Unlike vibration transducers, the shock pulse
Learn MoreBearing check and control are efficiently performed by the shock pulse method. The portable device BALTECH VP-3450 is designed to control a vibration level of rolling element bearings and lubricant condition in a bearing assembly. A bearing condition is evaluated by a color scale: green- good, yellow- warning, red- defect. View Product.
Learn More