Depuy Synthes | Proximal Femoral LCP plates - Which Medical Device

The proximal femoral locking compression plate (LCP) from Depuy-Synthes comes in a Hook Plate (to provide fixation of the trochanter) and non-hook plate version. Screws are 4.5/5.0mm, with combi-holes in the shaft allowing the placement of either. The most proximal screw hole accepts a 7.3mm cannulated locking of cannulated conical screw.

Learn More

2020-2025 Global Proximal Femoral Locking Plate Market Report

Proximal Femoral Locking Plate Industry Analysis and Market Research Report | Crediblemarkets.com 2020-2025 Global Proximal Femoral Locking Plate Market Report - Production and Consumption Professional Analysis (Impact of COVID-19) | Credible Markets

Learn More

Distal Femur VA-LCP Failures—Is There Really a Mechanical

With much interest we have read the article titled “Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate,” January  

Learn More

DePuy Synthes 3.5 mm/4.5 mm VA-LCP PPFx Proximal Femur

Proximal Femur Hook Plates, DePuy Synthes 3.5 mm VA Locking Attachment. Plate, DePuy Synthes 3.5 mm VA Locking PPFx Distal Femur Spanning.

Learn More

TomoFix® Lateral Distal Femur Plate | DePuy Synthes - J&J MedTech

The TomoFix Lateral Distal Femur Plate is designed according to the locking compression plate (LCP) principles and features both threaded locking and Combi holes. The TomoFix Lateral Distal Femur Plate is made of TAN (Ti-6Al-7Nb). The TomoFix Osteotomy System is a comprehensive plating system for stable fixation of osteotomies around the knee.

Learn More

Proximal Femur Fractures - Pediatric - Pediatrics - Orthobullets

proximal femur develops from 2 centers of ossification proximal femoral epiphysis ossification begins at 4-6 months in and 5-7 months in boys responsible for metaphyseal growth of femoral neck rate of growth is 3 mm/year accounts for 13-15% of overall leg length accounts for 30% of overall femur length trochanteric apophysis

Learn More

Proximal femur hook plate - DePuy Synthes Products, Inc

Proximal femur hook plate Document Type and Number: United States Patent 11344344 Abstract: A bone plate for treating periprosthetic fractures includes a head portion to be positioned along a greater trochanter of a bone. The

Learn More

The new VA-LCP Periprosthetic Proximal Femur Plating System

Proximal Femur Plate with GT Ring Attachment Plate, VA Locking Attachment Plate for these challenging fractures in cooperation with DePuy Synthes (DPS).

Learn More

Intramedullary nailing vs modular megaprosthesis in

2022/09/13 · Background Extracapsular proximal femur metastasis could be treated by synthesis or resection and megaprosthesis. No universal accepted guidelines are present in

Learn More

Biomechanical Analysis of the Proximal Femoral Locking

The proximal femoral locking compression plate. (PF-LCP; DePuy Synthes, Zuchwil, Switzerland) was intro- duced as a fixation option in 2007.6 A high failure 

Learn More

Femur compression bone plate / proximal LCP™ Depuy Synthes

The LCP™ Proximal Femoral Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The proximal portion of the plate is precontoured for the proximal femur. The two proximal screw holes are designed for 7.3 mm cannulated

Learn More

Early Mechanical Failures of the Synthes Variable Angle

Objectives: To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate.

Learn More

AD Carrothers and RG Turner - NCBI

The Synthes® technique guide for the locking compression proximal femoral plate advises that the plate is reduced on to the femur using a threaded 

Learn More

Proximal Femoral LCP plates - Depuy Synthes

The authors describe a high rate of mechanical failure in proximal locking plate fixation of the femur when fractures are unstable. Credits: 

Learn More

PDF LCP™ Proximal Femoral Hook Plate 4.5/5 - synthes.hs.llnwd.netPDF

LCP Proximal Femoral Hook Plate System The locking screws create a fixed-angle construct while using familiar AO plating techniques. Locking capability is important where screw purchase is compromised. These screws do not rely on plate-to-bone compression to resist patient load.

Learn More

Synthes-4.5mm-LCP-Proximal-Femur-Plate-Set in Mokena, IL, USA

Synthes-4.5mm-LCP-Proximal-Femur-Plate-Set. Category: General Medical Equipment in USA. Subcategory: Synthes. Listing ID: 74151757. Seller Reviews. See all reviews. Contact Seller

Learn More

DSEM-TRM-0714-0121-2_LR.pdf

The Synthes LCP Proximal Femoral Plate 4.5/5.0 is part of the. LCP Periarticular Plating System, which merges locking screw technology with conventional plating 

Learn More

LCP Pediatric Hip Plate. For osteotomy and trauma

Synthes 3 Characteristics Plate for trauma and derotation osteotomy The plate is available with a screw an-gle of 120 and 4 distal fixation screws. The plate has a universal design for the left and right proximal femur. The main

Learn More

Acu-Loc 2 Wrist Plating System | Acumed

The proximal plate end is tapered and the undersurface is designed for limited contact with the bone. Frag-Loc Compression Screw. The Frag-Loc Compression Screw is a two-part cannulated compression screw for dorsal comminution that gives surgeons the option for steadfast dorsal compression through a small dorsal incision. In addition, the

Learn More

LCP-Proximal-Femoral-Plates-Hook.pdf

The Synthes LCP Proximal Femoral Hook Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional 

Learn More

LCP Proximal Femoral Plate 4.5/5.0. Part of the LCP

10 DePuy Synthes LCP Proximal Femoral Plate 4.5/5.0 Surgical Technique Before a guide wire is inserted into the second wire guide, verify correct sagittal plane alignment of the plate on the

Learn More